Two-peg test exercise: predict the far reading from an equal-sight setup
Compute the peg elevation difference, predict a near-setup reading and diagnose a level line-of-sight bias without moving its adjustment screws.
On this page
Lay out the test on paperFind the elevation difference that survives the midpoint testAccount for the short sight tooExplain the practical consequenceA level gives convincing readings from the center of a test line and a noticeably different elevation difference near one end. Both observations can be internally repeatable. Use the unequal sight lengths to isolate the effect that canceled in the balanced setup.
Lay out the test on paper
Two stable pegs, A and B, are 60.0 m apart. An upright metric rod is placed on each. For the first setup the level is exactly halfway between them. For the second the level is on the line, 5.0 m from A and 55.0 m from B. Assume no rod settlement, negligible curvature and refraction at these distances, a constant line-of-sight tilt, and the same upright rod in both positions. Those assumptions define this teaching model.
| Setup | Distance to A | Distance to B | Reading on A | Reading on B |
|---|---|---|---|---|
| Midpoint | 30.0 m | 30.0 m | 1.522 m | 1.318 m |
| Near A | 5.0 m | 55.0 m | 1.100 m | 0.906 m |
Take the positive elevation difference to mean B above A. Calculate that difference using the balanced setup. Determine the expected B reading on the second setup if both readings had the same line-of-sight bias as the near reading. Compare it with the observed far reading. Express the inferred bias per metre of additional sight length.
Find the elevation difference that survives the midpoint test
At equal sight lengths, a line-of-sight tilt adds the same signed reading error on the two rods under the assumptions above. Subtracting cancels that common error. The elevation difference B minus A is 1.522 − 1.318 = +0.204 m. B is higher, which explains why it has the smaller rod reading from the same instrument setup.
On the near setup, using the observed A reading as the reference gives an expected far reading of 1.100 − 0.204 = 0.896 m if the two sight biases were equal. The observed B reading of 0.906 m is 0.010 m larger. Equivalently, the near setup reports B minus A as 1.100 − 0.906 = +0.194 m, 0.010 m less than the balanced result.
Account for the short sight too
The excess 0.010 m arises across 55 − 5 = 50 m of additional sight distance. Under the linear bias model the reading increases by 0.010 / 50 = 0.0002 m per metre, or 0.2 mm per metre. The sign indicates a line of sight that rises with distance for these staff readings. Dividing by the full 60 m peg spacing would treat the instrument as though it stood on A and would understate the slope.
Check the inferred result by estimating the errors separately. At 5 m the excess is +0.001 m. At 55 m it is +0.011 m. Subtract each from its measured reading to obtain 1.099 and 0.895 m. The resulting difference is again +0.204 m. The 0.896 m value found earlier includes the near sight’s own 1 mm bias and should not be confused with the bias-free far reading.
Explain the practical consequence
Even with this modeled tilt, a leveling run with closely balanced backsight and foresight lengths suppresses its effect on each elevation difference. A large imbalance allows more of the error to enter the result. The two-peg exercise shows the mechanism; it does not establish that a particular instrument is within its manufacturer’s tolerance or prescribe an adjustment.
A complete student report states the positive direction, both distances from the instrument, the independent midpoint difference and the discrepancy per unit distance. Then explain what could invalidate the inference: a moved peg, an unplumb rod, changing refraction or a poor reading could also change the result. A repeat test under the applicable procedure can separate a repeatable instrument characteristic from a single bad observation.